ALM-3632 DRU extended 1F alarm

Description

This is the alarm user defined and the alarm name and description can be customized.

Attribute

Alarm ID Alarm Severity Alarm Type
3632 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:DRU

3 Board No.

Number of the fault board

0:DRU0

1:DRU1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Undefined.

System Actions

None.

Possible Causes

Undefined.

Procedure


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.