ALM-3640 Frame or Timeslot Number alarm

Description

This alarm is triggered when the frame or timeslot number received by the DSP is incorrect or the direct memory access (DMA) is interrupted due to IOMU clock/hardware failure.

Attribute

Alarm ID Alarm Severity Alarm Type
3640 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:DRU

3 Board No.

Number of the fault board

0:DRU0

1:DRU1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

All the services supported by the DRU will be interrupted upon the occurrence of this alarm.

System Actions

None.

Possible Causes

  • The 13 M clock of the IOMU is unavailable.
  • The clock circuit of the DRU is faulty.
  • The frame number receiving chip in the DRU is faulty.

Procedure

  1. Check whether there is any correlated alarm

    Check whether 3692 IOMU Clock Alarm exists in the LMT.

    y=>Handle 3692 IOMU Clock Alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 2.

    N=> Go to Step 2.

  2. Reset the BTS

    Perform fourth-level reset on the BTS3002C or reset it by power-down (recommended) through the LMT or local maintenance system. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

  3. Remove and insert the MCU and DRU

    Power down the BTS3002C. Remove and insert the MCU and DRU in the backplane. Power up the BTS3002C and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 4.

  4. Replace the MCU and DRU and see if the alarm is cleared

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared.Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.