ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:DRU |
3 | Board No. | Number of the fault board 0:DRU0 1:DRU1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 9: BTS3002C |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When the alarm occurs, the system will automatically shut off the power amplifier and the DRU services will be interrupted.
When the alarm occurs, the system will automatically shut off the power amplifier. In ten minutes it will detect whether the DRU temperature is back to normal. If yes, it will turn on the power amplifier. Otherwise, it will detect the temperature in another ten minutes. If the temperature remains high after three successive detection failures, the system will quit turning on the power amplifier.
Wait for about 30 minutes. Check whether the alarm disappears automatically.
Y=> The alarm handling ends.
N=> Go to Step 2.
Perform fourth-level reset on the BTS3002C through the LMT or local maintenance system. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> The hardware in the system might fail. Check and record the DRU temperature according to Check the temperature of the DRU .Please contact Huawei Customer Service Center.