ALM-3660 DRU Temperature Critical alarm

Description

This alarm is triggered when the DRU temperature is higher than the the high temperature major alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
3660 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:DRU

3 Board No.

Number of the fault board

0:DRU0

1:DRU1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm occurs, the system will automatically shut off the power amplifier and the DRU services will be interrupted.

System Actions

When the alarm occurs, the system will automatically shut off the power amplifier. In ten minutes it will detect whether the DRU temperature is back to normal. If yes, it will turn on the power amplifier. Otherwise, it will detect the temperature in another ten minutes. If the temperature remains high after three successive detection failures, the system will quit turning on the power amplifier.

Possible Causes

  • The heating board in the DRU is faulty.
  • The DRU hardware is faulty.
  • The cooling system in the DRU fails.

Procedure

  1. Wait for the alarm to be cleared automatically

    Wait for about 30 minutes. Check whether the alarm disappears automatically.

    Y=> The alarm handling ends.

    N=> Go to Step 2.

  2. Reset the BTS

    Perform fourth-level reset on the BTS3002C through the LMT or local maintenance system. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> The hardware in the system might fail. Check and record the DRU temperature according to Check the temperature of the DRU .Please contact Huawei Customer Service Center.