ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:DRU |
3 | Board No. | Number of the fault board 0:DRU0 1:DRU1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 9: BTS3002C |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Wait for about 30 minutes. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to step 2.
Note:
Manual handling is required if the alarm is frequently reported and cleared.
To check the DRU temperature through the following operations:
Note:
HW_ALM_THD_HIGHTEMPERATURE: 65;HW_ALM_THD_LOWTEMPERATURE: -5.
Perform fourth-level reset on the BTS3002C through the LMT or local maintenance system. Check whether the alarm is cleared.
Y=>The alarm handling is complete.
N=>The DRU hardware might be faulty.Please contact Huawei Customer Service Center and report the DRU temperature to it.