ALM-3668 Transmission Loop Test Alarm

Description

This alarm is triggered when a user delivers the command to start the IOMU E1 loopback test or IASU loopback test on the BTS3002C through the maintenance system.

Attribute

Alarm ID Alarm Severity Alarm Type
3668 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:IOMU

3 Board No.

Number of the fault board

0:IOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:start BSC-oriented loopback test

1:start IOMU MPC860 oriented loopback test

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm occurs, the communications between the BTS3002C and the BSC and the services in the BTS3002C will be interrupted.

System Actions

When the test time is up, the BTS3002C resets automatically and resumes to normal operation.

Possible Causes

An IOMU E1 loopback test or IASU loopback test is started.

Procedure

  1. The system reports this warning when an E1 loopback test or IASU loopback test is started manually. No manual handling is required.


Huawei Proprietary and Confidential