ALM-3684 Rack ID error alarm

Description

When detecting the DRU rack No. is wrong, IOMU corrects the error and reports this alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
3684 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:IOMU

3 Board No.

Number of the fault board

0:IOMU 0

1:IOMU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

None.

Procedure

  1. Check the DIP switch of the DRU backplane and weld it again.

  2. Replace the backplane.


Huawei Proprietary and Confidential