ALM-3702 Version Rollback Alarm

Description

During reboot, the IOMU will check the version stack and select a running version. This alarm is triggered when the version in the previous operation is invalid, and then the version will fall back automatically.

Attribute

Alarm ID Alarm Severity Alarm Type
3702 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:IOMU

3 Board No.

Number of the fault board

0:IOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

1:The IOMU software version falls back from the first version in the FLASH.

2:The IOMU software version falls back from the second version in the FLASH.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm occurs, the problems caused by version inconsistency may occur.

System Actions

None.

Possible Causes

  • The IOMU resets within five minutes since the activation of the IOMU software.
  • The running version in the Flash Memory of the IOMU is erased.

Procedure

  1. Load and activate the updated IOMU software. Check whether the alarm is cleared.

    Y=>The alarm handling ends.

    N=>Please contact Huawei Customer Service Center


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.