ALM-3722 Software Not Activated Alarm

Description

This alarm is triggered when IOMU detects that the DRU software has not been activated.

Attribute

Alarm ID Alarm Severity Alarm Type
3722 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:IOMU

3 Board No.

Number of the fault board

0:IOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm occurs, the relevant DRU cannot work normally or the running software version on the DRU is an informal one.

System Actions

When the alarm occurs, the intelligent algorithm in the BTS3002C will automatically search for a software version that can run and then activate it. If there is no software available for the DRU, the DRU cannot start up.

Possible Causes

The software of the DRU in the BTS3002C has not been activated.

Procedure

  1. Load and activate all the DRU software in theBTS3002C. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.