ALM-3842 EAC Communication Alarm

Description

This alarm is reported when the EAC communication is abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
3842 Critical Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

13:EAC

3 Board No.

Number of the fault board

0:EAC0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The alarms related to environment monitoring cannot be reported.

System Actions

None.

Possible Causes

  • The corresponding EAC is not installed or powered on.
  • Communication between the corresponding EAC and the IOMU is abnormal.
  • This alarm may be generated when the BTS is reset and it will auto disappear after successful reset.

Procedure

  1. Check if the EAC (environment alarm box) is installed or powered on.

    Y=>Go to Step 3.

    N=>Go to Step 2.

  2. Install the corresponding EAC and power it on. See if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>Go to Step 3.

  3. Check if the communication interface cable of the EAC is properly connected.

    Y=>Go to Step 5.

    N=>Go to Step 4.

  4. Connect the communication interface cable of the EAC and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>Go to Step 5.

  5. Replace the EAC and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>Go to Step 6.

  6. Check other boards on CBUS3.Disconnect all the communication cables of the CDU, EDU, TES, and PMU on CBUS3 and see if the alarm is cleared.

    Y=>Go to Step 7.

    N=>Go to Step 8.

  7. Replace the faulty board.

    Alarm handling is completed.

  8. Reset the IOMU and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>Go to Step 9.

  9. Replace the IOMU and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared.Please contact Huawei Customer Service Center.