ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 85:APM |
3 | Board No. | Number of the fault board 0:PMU0 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:low voltage power off 1:MCU controlled power off 2:high temperature power off |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 9: BTS3002C |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
MCU controlled power off: Go to Step 2.
Low voltage power off: Go to Step 2.
High temperature power off: Go to Step 3.
Check on site if the AC power supply input to the BTS fails.
Y=>Go to Step "Handle the problem in AC power supply failure and see if the alarm is cleared".
N=>Go to Step 4.
Handle the problem in AC power supply failure and see if the alarm is cleared.
Y=>Alarm handling is completed.
N=>Go to Step 4.
Lower the temperature inside the cabinet and see if the alarm is cleared.
Y=>Alarm handling is completed.
N=>The alarm is not cleared. Go to Step 4.
Y=>Alarm handling is completed.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center