ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 85:APM |
3 | Board No. | Number of the fault board 0:PMU0 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 9: BTS3002C |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
This alarm is generated when the PMU detects that the ambient temperature is below than the set lower limit.
Check if the lower limit of the temperature is set properly.
Y=>Go to Step 2.
N=>Go to Step "Reset the lower limit of the temperature and see if the alarm is cleared".
Re-set the lower limit of the temperature and see if the alarm is cleared.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Go to Step 2.
Check if the heat exchanger works normally.
Y=>Go to Step 3.
N=>Go to Step Check the heat exchanger and ensure that it works normally. see if the alarm is cleared".
Check the heat exchanger and ensure that it works normally. See if the alarm is cleared.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Go to Step 3.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.