ALM-3954 Door Alarm

Description

This alarm is reported when the door is opened.

Attribute

Alarm ID Alarm Severity Alarm Type
3954 Critical Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

85:APM

3 Board No.

Number of the fault board

0:PMU0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

9: BTS3002C

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

This alarm is generated when the APM cabinet is opened.

Procedure

  1. Check if someone opens the cabinet door.
    1. Check if it is the maintenance engineer that opens the APM cabinet door.

      Y=>Go to Step 3.

      N=>No maintenance engineer opens the APM cabinet door. Go to Step b.

    2. Check on site if someone opens the APM cabinet door illegally.

      Y=>Go to Step c.

      N=>Go to Step 2.

    3. .
  2. Check if the sensor is faulty.

    Check if the door status sensor is faulty. Replace it if necessary and then go to Step [3].

  3. Clear the alarm.

    NOTE:

    Ensure normal operation of the sensor when clearing the alarm. Otherwise, the alarm cannot be cleared.