ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 65:DTRU/GTRU/DDRM 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU 151:QTRU |
3 | Board No. | Number of the fault board |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: TMU subcommand configuration error alarm 1: Board type configuration error alarm (board type: PTRX) 2: Board type configuration error alarm (board type: DTRX) 3: Board type configuration error alarm (board type: ETRX) 4: Board type configuration error alarm (board type: RTRX) 5: Board type configuration error alarm (board type: GT800) 6: Board type configuration error alarm (board type: PETR) 7: Board type configuration error alarm (board type: EETR) 8: TRX power decrease alarm 9: Frequency and TRX type mismatch (for the BTS3012 series) 21: Board ranSharing attributes configuration abnormal 22: Arfcn configuration Disable 23: Board frequency band outrange 24: Board frequency interval abnormal 25: Board power over configuration 26: Board UMTS configuration conflict 27: TRX configuration attributes abnormal 28: Frequency and TRX type mismatch (for the BTS3900 series) 29: MLCC configuration abnormal alarm 30: Trx Attributes configuration abnormal 31: Tx combine mode configuration and jumper physical connection mismatch 32: Jumper physical abnormal 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The system automatically shuts down the PA when this alarm is generated. When the alarm is cleared, the TRX automatically turns on the PA.
Log in to the LMT, select the browse mode, and then check whether the following data configurations are correct:
(1) Check the channel attributes.
(2) Check the CCCH parameters in the system information.
(3) Check the channel type configuration.
Y => The data configuration is correct. Go to procedure 2.
N => The data configuration is incorrect. Go to procedure 2.
Reset the site in level 4 on the LMT or the SMT. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Replace the board in the slot according to the data configuration. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step b.
Set up the cell again. Ensure that the system types of the cell are consistent with the actual board types. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Check whether the power level of the TRX in the data configuration is within the operating range of the RF front end. The range is determined by the power type of the DDPU, for example, supporting 60 W.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step b.
Check the RF front end.. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Log in to the LMT, and check whether the configured ARFCNs are consistent with the actual TRX types.
Y => The configured ARFCNs are consistent with the actual TRX types, yet the alarm is not cleared. Contact Huawei Customer Service Center.
N => The configured ARFCNs are inconsistent with the TRX types. Change the ARFCNs to be consistent with the TRX band. No further action is required.
Log in to the LMT, and check whether the configured ARFCNs are consistent with the actual TRX types.
Y => The configured ARFCNs are consistent with the actual TRX types, yet the alarm is not cleared. Contact Huawei Customer Service Center.
N => The configured ARFCNs are inconsistent with the TRX types. Change the ARFCNs to be consistent with the TRX band. No further action is required.
Check the Trx configuration.
Log in to the LMT,andCheck the configuration information on the LMTto check the config data is right or not.
Y => Configuration is right,can not find the error,Contact Huawei Customer Service Center;
N => Find out the error,adjust the config data. No further action is required.
Log in to the LMT, select the browse mode, and then check whether the following data configurations are correct:
(1) Check the channel attributes.
(2) Check the CCCH parameters in the system information.
(3) Check the channel type configuration.
(4) Check frequency configuration.
(5) Check the configuration information on the LMT.
(6) Check the assigned frequency.
Y => The data configuration is correct. Go to procedure 2.
N => The data configuration is incorrect. Go to procedure 5.
Reset the site in level 4 on the LMT or the SMT. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Log in to the LMT, and check whether the configured ARFCNs are consistent with the actual TRX types.
Y => The configured ARFCNs are consistent with the actual TRX types, yet the alarm is not cleared. Contact Huawei Customer Service Center.
N => The configured ARFCNs are inconsistent with the TRX types. Change the ARFCNs to be consistent with the TRX band. No further action is required.
The current BTS version is not compatible. Contact Huawei Customer Service Center.
Log in to the LMT, and select the browse mode.
Check that Current Power Mode of the TRX is smaller than its Maximum Power Mode.
Y => The data configuration is correct. Go to procedure 5.
N => The data configuration is incorrect. Modify the data configuration. Lower the configured power.
Replace the board in the slot according to the data configuration. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step b.
Set up the cell again. Ensure that the system types of the cell are consistent with the actual board types. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => The combination mode in data configuration is consistent with the connections of jumpers. Contact Huawei Customer Service Center.
N => The combination mode in data configuration is inconsistent with the connections of jumpers. Go to sub-step b.
If the connections of jumpers for combination on the panel of the module are incorrect, change the connections of jumpers in the equipment room.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
In the equipment room of the base station, check whether the jumpers for combination on the panel of the module are faulty, such as disconnection, improper contact, and damage.
Y => The jumpers are functional. Contact Huawei Customer Service Center.
N => The jumpers are faulty. Go to sub-step b.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.