4106 TRX Software Running Abnormal Alarm

Description

This alarm is reported when the processor in the Carrier Module runs abnormally.

Attribute

Alarm ID Alarm Severity Alarm Type
4106 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The DTRU reports this alarm upon detecting that an LAPD link is not available.

System Actions

When this alarm occurs, the system shuts off the power amplifier automatically. For the DTRU of main BCCH, DTRU mutual aid is started.

Possible Causes

  • CPU runs abnormally
  • CPU runs abnormally
  • The DSP software or the mailbox communication is faulty
  • Incorrect software version

Procedure

  1. Check if the DTRU software version is right.

    Check if the DTRU software version is right.

    Y=> Go to Step 2.

    N=> Go to Step 2.

  2. Load the right software version.

    Load the right software version and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm Handling is completed.

    N=>The alarm is not cleared. Go to Step 3.

  3. Reset the BTS.

    Reset the BTS on the LMT and see if the alarm is cleared.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. Go to Step 4.

  4. Plug in and out the main control module and DTRU module.

    Power off the BTS, plug in and out the main control module and DTRU module, power on again and see if the alarm is cleared.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. The fault may lie in faulty DTRU hardware. Please contact Huawei Customer Service Center.