4120 TRX DBUS Alarm

Description

This alarm is reported when the DBUS clock of the TRX is abnormal or the TRX hardware detects that the DBUS signal sent by the main control module is lost.

Attribute

Alarm ID Alarm Severity Alarm Type
4120 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services will be interrupted when the alarm is generated.

System Actions

Check if the alarm is cleared every certain period of time.

Possible Causes

  • The cable distribution of the rack is faulty.
  • The backplane of the DTRU subrack is faulty.
  • The signal transfer card is faulty.
  • The backplane of the main control module is faulty.
  • The main control module is faulty.
  • The DTRU hardware is faulty.
  • The E1 transmission cable is faulty.
  • The DBUS of the rack is faulty.

Procedure

  1. Replace the cable distribution of the rack.

    Replace the cable distribution of the rack, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 2.

  2. Replace the backplane of the DTRU subrack.

    Replace the DTRU, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 3.

  3. Replace the signal transfer card.

    Replace the signal conversion card, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 4.

  4. Replace the backplane of the main control module.

    Replace the backplane of the main control module, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 5.

  5. Replace the main control module.

    Replace the main control module, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.


Huawei Proprietary and Confidential