ALM-4134 TRX maintenance alarm

Description

This alarm is reported when the download software of the TRX does not support certain hardware installed on the TRX.

Attribute

Alarm ID Alarm Severity Alarm Type
4134 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • When this alarm is generated, the TRX directly runs the download software if the memory (download Flash or ROM) of the TRX has available download software.
  • Thus, the version of the running download software is inconsistent with the expected version. The version number of the running download software is obtained from only the BTS log of the related TRX. The version queried from LMT is invalid.

System Actions

When this alarm is generated, the TRX directly runs the download software if the download Flash has available download files. Otherwise, the TRX directly runs the download software in the ROM.

Possible Causes

The download software does not support the CPU installed on the TRX.

Procedure

  1. Check whether the Sub No. of the alarm is 0.

    Y=> Go to step 2.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center .

  2. Download and activate software that supports the CPU installed on the TRX.

    Observe whether the alarm is cleared after the handling.

    Y=> The alarm is cleared. Alarm handling is complete.

    N=> The alarm is not cleared. ]Please contact Huawei Customer Service Center[/hw].


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.