414 Manually Obturate Channel

Description

This alarm is reported when a channel is manually obturated.

Attribute

Alarm ID Alarm Severity Alarm Type
414 Minor Event

Parameters

ID Name Meaning
1 Site No.

Number of the site whose channel is obturated.

2 Cell No.

Number of the cell whose channel is obturated.

3 Trx No

Number of the trx whose channel is obturated.

4 Channel number

Number of the channel which is obturated.

5 Block type

0 = LOCK, 2 = SHUTDOWN

6 Site Name

Name of the site whose channel is obturated.

7 Cell Name

Name of the cell whose channel is obturated.

8 Cell CGI

Cell Global Identifier of the cell whose channel is obturated.

9 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

The channel is unavailable.

System Actions

None.

Possible Causes

The channel is manually blocked.

Procedure

  1. None.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.