4140 TRX Temperature Too High Alarm

Description

This alarm is reported when the temperature of the power amplifier exceeds 90oC.

Attribute

Alarm ID Alarm Severity Alarm Type
4140 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

All the services of the DTRU will be interrupted upon occurrence of this alarm.

System Actions

  • When this alarm occurs, the system shuts off the power amplifier automatically. For the DTRU of main BCCH, DTRU mutual aid is started.

Possible Causes

  • Over high environment temperature.
  • Heat dissipation system runs abnormally.
  • Faulty BTS hardware.

Procedure

  1. Check the ambient temperature of the BTS.

    Power off the TRX. For the indoor BTS, the indoor temperature must be lower than 25℃. For the outdoor BTS, the DHEU must be running normally. Then, power on the TRX.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 2.

  2. Check for the Fan Not In-Position Alarm of the BTS.

    Power off the TRX. Take measures to clear the Fan Not In-Position Alarm. After ten minutes later than you clear the alarm, power on the TRX.

    Y => The alarm is reported. Rectify the fault according to the handling suggestions of Fan Not In-Position Alarm. After a while, check whether the alarm is cleared.

    N => The alarm is not reported. Go to step 3.

  3. Replace the DTRU.

    Replace the DTRU, and then check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.