ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 65:DTRU/GTRU/DDRM 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU 151:QTRU |
3 | Board No. | Number of the fault board |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Replace the DCCU, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to procedure 2.
Replace the main control module, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to procedure 3.
Replace the TRX, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to procedure 4.
Replace the rack, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.