4156 TRX slave clock alarm

Description

A Carrier Module reports this alarm when detecting that the slave clock signal input to it is not available.

Attribute

Alarm ID Alarm Severity Alarm Type
4156 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

If a DTRU Main Clock Alarm is also reported when this alarm occurs, the services of the DTRU will be interrupted completely.

System Actions

Check if the alarm is cleared every certain period of time.

Possible Causes

  • The standby main control module is not installed.
  • The DCCU is faulty.
  • The main control module is faulty.
  • The DTRU hardware is faulty.
  • The cable distribution of the rack is faulty.

Procedure

  1. Reinstall the standby DTMU.

    Remove and reinstall the standby DTMU. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 2.

  2. Replace the DCCU.

    Replace the DCCU, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 3.

  3. Replace the main control module.

    Replace the main control module, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 4.

  4. Replace the DTRU.

    Replace the DTRU, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 5.

  5. The cable distribution of the rack is faulty.

    Replace the rack, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.