ALM-4180 TRX type not support alarm

Description

The alarm is triggered when the power type of a 40W Carrier Module is set to 60W.

Attribute

Alarm ID Alarm Severity Alarm Type
4180 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The coverage area reduces.

System Actions

The DTRU automatically adopts the default power type.

Possible Causes

  • The power type of a 40W DTRU is set to 60W.
  • Data configuration error.

Procedure

  1. Check whether the power type is consisitent with the DTRU power type.

    Y=> The alarm cause cannot be located. Please contact Huawei Customer Service Center.

    N=> Modify the configuration of the Carrier Power Type in the Device Property tab. Alarm handling is completed.