4194 Board type mismatch alarm

Description

The alarm is reported when the type of a board actually installed in a slot of the rack is different from that of the board configured in the same slot at the BSC side.

Attribute

Alarm ID Alarm Severity Alarm Type
4194 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

1: the Board type is PTRX

2: the Board type is DTRX

3: the Board type is ETRX

4: the Board type is RTRX

5: the Board type is GT800

6: the Board type is PETR

7: the Board type is EETR

8: the Board type is QTRU

9: the Board type is DRFU

10: the Board type is MRRU

11: the Board type is XRRU

12: the Board type is MRFU

13: the Board type is GRFU

14: the Board type is GRRU

15: the Board type is XRFU

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The DTRU in the slot where alarm is generated cannot work.

System Actions

The DTRU is back to normal when the alarm is cleared.

Possible Causes

The board type actually installed in the slot of the rack is different from the data configured in the slot at the BSC side.

Procedure

  1. Replace the board according to the system configuration.
    1. Check the type of the board in the faulty slot in the system configuration.
    2. Replace the board according to the queried board type.
    3. Check whether the alarm is cleared:

      Y => The alarm is cleared. The alarm handling ends.

      N => The alarm is not cleared. Contact Huawei Customer Service Center.