ALM-4214 SFP Module fault Alarm

Description

SFP Module fault Alarm

Attribute

Alarm ID Alarm Severity Alarm Type
4214 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

3 Board No.

Number of the fault board

0-71:DRRU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:master port

1:slave port

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

BBU and RRU are not communicated.

System Actions

None.

Possible Causes

The SFP is abnormal.

Procedure

  1. Check the SFP module

    Check whether the SFP module is good or not,if there is any problem,Please contact Huawei Customer Service Center.

  2. Replace the optical line or the SFP module

    Replace the optical line or the SFP module,check if the alarm is cleared.

    Y=> The alarm is cleared.

    N=> Go to Step 3.

  3. CPRI loop

    CPRI loop in the side of RRU,if there is any problem,it maybe the fault of the FPGA or CPRI version,Please contact Huawei Customer Service Center.

    If no problem is exist,the problem is CPRI fault exist in the side of BBU, Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.