ALM-4218 Temperature Prompt Alarm

Description

This alarm is reported when the temperature of the carrier module board or the power amplifier exceeds 90oC.

Attribute

Alarm ID Alarm Severity Alarm Type
4218 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

  • The environment temperature is too high.
  • The heat dissipation system is abnormal.
  • The hardware of the BTS is faulty.

Procedure

  1. Wait for the system self-processing.

    Check if the alarm is cleared after system self-processing.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. If the TRX is outdoor series, go to Step [2], else go to Step [3].

  2. Check if there is a fan alarm.

    If yes, handle the fan alarm. Check if the PAU temperature alarm is cleared after the fan recovers.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. Go to Step 3.

  3. Check the working environment arround the BTS.Check if the temperature exceeds 55oC.

    Y=> Reduce the temperature. Check if the alarm is cleared. The alarm is cleared. Alarm handling is completed. The alarm is not cleared. Go to Step 4.

    N=> Go to Step 4.

  4. Relace the faulty DTRU.

    Replace the faulty DTRU and see if the alarm is cleared.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential