ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU |
3 | Board No. | Number of the fault board 0-71:DRRU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:ANT A over current 1:ANT A under current 2:ANT A over current protect 3:ANT A under current protect 4:ANT B over current 5:ANT B under current 6:ANT B over current protect 7:ANT B under current protect 8:RET PORT over current 9:RET PORT under current 10:RET PORT over current protect 11:RET PORT under current protect |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Once the alarm is generated, the RET antenna functionality of the TRX is disabled.
Shut down the RET antenna and restart it. Then, check whether the alarm is cleared.
Y=> The alarm is cleared. The alarm handling is complete.
N=> Go to step 3.
Replace the RET antenna, and then check whether the alarm is cleared.
Y=> The alarm is cleared. The alarm handling is complete.
N=> Go to step 4.
Replace the TRX, and then check whether the alarm is cleared.
Y=> The alarm is cleared. The alarm handling is complete.
N=> The alarm persists. Please contact Huawei Customer Service Center.