ALM-4226 ALD Current Abnormal Alarm

Description

This alarm is generated when the current carried on the 12 power supply circuit for the RET antenna is greater than 3 A.

Attribute

Alarm ID Alarm Severity Alarm Type
4226 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

3 Board No.

Number of the fault board

0-71:DRRU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:ANT A over current

1:ANT A under current

2:ANT A over current protect

3:ANT A under current protect

4:ANT B over current

5:ANT B under current

6:ANT B over current protect

7:ANT B under current protect

8:RET PORT over current

9:RET PORT under current

10:RET PORT over current protect

11:RET PORT under current protect

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Once the alarm is generated, the RET antenna functionality of the TRX is disabled.

System Actions

The TRX stops supplying power to the RET antenna.

Possible Causes

  • The RET antenna is short-circuited or faulty.
  • The TRX detection circuit for the RET antenna is faulty.

Procedure

  1. Check whether the power cable and its connector are securely connected.
    1. Check whether the power cable and its connector are securely connected.

      Y=> Go to step 1.

      N=> Go to step b.

    2. Reconnect the cable and the connector.

      Check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to step 2.

  2. Check the RET antenna.

    Shut down the RET antenna and restart it. Then, check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> Go to step 3.

  3. Replace the RET antenna.

    Replace the RET antenna, and then check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> Go to step 4.

  4. Replace the TRX.

    Replace the TRX, and then check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> The alarm persists. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.