ALM-4230 Dry Contact 2 Alarm

Description

This alarm is the external Boolean alarm related to the DRRU, GRRU, or MRRU. The specific alarm source is subject to site configurations.

Attribute

Alarm ID Alarm Severity Alarm Type
4230 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

88:DRRU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

92:DRFU

3 Board No.

Number of the faulty board or module

0-8:DEMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

20:DBS3036;

21:BTS3036;

22:BTS3036A;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The alarm configured by the user is generated and the corresponding impact occurs.

System Actions

None.

Possible Causes

The data configuration is inconsistent with the corresponding external Boolean alarm, or the external device is faulty. The specific alarm source is subject to site configurations.

Procedure

  1. Check the consistency between the Boolean alarm configuration and the physical connections.
    1. Check whether the Boolean alarm configuration is consistent with the physical connections.

      Y => The Boolean alarm configuration is consistent with the physical connections. Go to procedure 2.

      N => The Boolean alarm configuration is inconsistent with the physical connections. Go to step b.

    2. Reconfigure the Boolean alarm. Check whether the alarm is cleared.

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Contact Huawei.

  2. Check the sensor for the external device and related cable connections.
    1. On site, check whether the sensor for the external device and related cable connections are faulty.

      Y => The sensor for the external device or related cable connections are faulty. Go to step b.

      N => The sensor for the external device and related cable connections are normal. Contact Huawei.

    2. Replace the faulty sensor, or reinstall the sensor-related cables. Check whether the alarm is cleared.

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Contact Huawei.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.