ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site whose soft vision is inconsistent. |
2 | VersionNo | Error VersionNo |
3 | Site Name | Site Name |
4 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
When this alarm is reported, the related BTS software cannot be automatically loaded.
When the user fails to configure the correct BTS software version and the automatic loading mode is used, this alarm is generated.
Y => Go to 2.
N => Change the software version in the BTS Attributes to the version to be loaded. The alarm handling is complete.
Y => This is a history alarm. No handling is required.
N => This is not a history alarm. Contact Huawei Customer Service Center.