ALM-4710 E1/T1 Remote Loop Test Alarm

Description

The alarm is reported when an E1 loopback test command is sent to the BTS through the BSC maintenance system.

Attribute

Alarm ID Alarm Severity Alarm Type
4710 Critical Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DTMU/DOMU

87:GTMU

3 Board No.

Number of the fault board

0-7:DTMU/DOMU/GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The BTS cannot communicate with the BSC and the BTS services are interrupted upon occurrence of this alarm.

System Actions

The BTS automatically resets and is back to normal when the test time is out.

Possible Causes

E1 self loop test.

Procedure

  1. This alarm is a warning reported upon manual remote loopback test. No manual handling is required for it.


Huawei Proprietary and Confidential