ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 64:DTMU/DOMU 87:GTMU 129:TMU |
3 | Board No. | Number of the fault board 0-7:DTMU/DOMU/GTMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 3:BTS30; 5:BTS312; 10:BTS3012A; 11:BTS3006A; 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Download and activate the latest TMU software version of the BTS. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to Step 2.
Power down the BTS, reset and power it up. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to Step 3.
Replace the TMU and check whether the alarm is cleared.
Y=> The alarm handling ends.