ALM-4764 SW Not Activated Alarm

Description

This alarm is reported when the TRX board software is not activated.

Attribute

Alarm ID Alarm Severity Alarm Type
4764 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DTMU/DOMU

87:GTMU

3 Board No.

Number of the fault board

0-7:DTMU/DOMU/GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

There is no impact on services but the features of new versions may be unusable.

System Actions

None.

Possible Causes

The downloaded software of the TRX board is not activated.

Procedure

  1. Activate the software. Check whether the software activation is successful.

    Y => The software activation is successful. Go to procedure 4.

    N => The software activation fails. Go to procedure 2.

  2. Check whether the software version to be activated is correctly loaded to the OMU or GBAM on the BSC.

    Y => The software version is correctly loaded. Go to procedure 4.

    N => The software version is incorrectly loaded. Go to procedure 3.

  3. According to the software configuration requirements, load the software to the OMU or GBAM on the BSC. Perform the software activation. Then, check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Go to procedure 4.

  4. Check whether there is a board that is installed and powered on but not configured on the LMT.

    Y => There is such a board. Go to procedure 5.

    N => There is no such board. Contact Huawei Customer Service Center.

  5. Power off the board. Alternatively, configure, activate, and then delete the board on the LMT. Check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.