ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 64:DTMU/DOMU |
3 | Board No. | Number of the fault board 0-7:DTMU/DOMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Y=>The surge protection unit has an LED. Go to 2.
N=> The surge protection unit does not have any LED. Go to 3.
Y=>If the LED is red, replace the surge protection unit.
To replace the surge protection unit, power off the cabinet, remove the faulty surge protection unit, and install a new surge protection unit. Then, check whether the alarm is cleared.
Y=>The alarm is cleared. End alarm handling.
N=>The alarm is not cleared. Go to step b.
N=>If the LED is green, go to step b.
Check the alarm cable between the surge protection unit and the DSAC to ensure that the alarm cable is properly connected. Then, check whether the alarm is cleared.
Y=>The alarm is cleared. End alarm handling.
N=>The alarm is not cleared. Contact Huawei Customer Service Center.
Y=>The alarm is cleared. End alarm handling.
N=>The alarm is not cleared. Go to step b.
Y=>The alarm is cleared. End alarm handling.
N=>The alarm is not cleared. Contact Huawei Customer Service Center.