ALM-4806 DTMU Inverse Alarm

Description

This alarm is reported when the active DTMU and the standby DTMU is switched over.

Attribute

Alarm ID Alarm Severity Alarm Type
4806 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DTMU/DOMU

87:GTMU

3 Board No.

Number of the fault board

0-5:DTMU/GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number.

Sub No.0: The opposite board is pulled out.

Sub No.1: The CPU on the opposite board is down.

Sub No.2: Manual switchover.

Sub No.3: Writing/reading the Flash error

Sub No.4: The opposite board SD539 Chip initialized improperly.

Sub No.5: The 32 MHz clock on the opposite board is abnormal.

Sub No.6: The FPGA of the opposite board is abnormal.

Sub No.7: The 2 MHz clock on the opposite board is abnormal.

Sub No.8: The E1 Chips on the opposite board is initialized improperly.

Sub No.9: The E1 circuit of the opposite board is abnormal.

Sub No.10: The main clock of the opposite board is abnormal.

Sub No.11: The internal power supply of the opposite board is abnormal.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

This alarm prompts you that the active/standby DTMU switchover occurs. It indicates that the services of the BTSs are interrupted for a while.

System Actions

None.

Possible Causes

The active DTMU and the standby DTMU are switched over. The causes of the switchover are as shown in the Sub No. of the Parameter table.

Procedure

  1. Clear this alarm.

    Right-click this alarm in the Browse Alarm pane and select Manually Clear Alarm on the shortcut menu.

  2. Check whether the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is complete.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.