ALM-4812 Optic Module Abnormal Alarm

Description

This alarm is generated under the following circumstances: An exception occurs in the optical signals received by or transmitted from optical module A or B.

Attribute

Alarm ID Alarm Severity Alarm Type
4812 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Type of the site where the faulty board or module is located

13: BTS3006C

14: BTS3002E

3 Board No.

Identity of the faulty board or module

64:DTMU/DOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm Sub-Category Number

Sub No. 0: An exception occurs in the optical signals received by or transmitted from optical module A.

Sub No. 1: An exception occurs in the optical signals received by or transmitted from optical module B.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

0:BTS22C;

2:BTS20;

3:BTS30;

5:BTS312;

7:BTS3001C-108 or BTS3001C-116;

8:BTS3001C-204;

9:BTS3002C;

10:BTS3012A;

11:BTS3006A;

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

20:DBS3036;

21:BTS3036;

22:BTS3036A;

29:BTS3900B;

30:BTS3900E.

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

0=Normal,1=Transient Count

Impact on the System

The service performance is deteriorated, or the service is disrupted.

System Actions

None.

Possible Causes

  • Tributary No. 0: Optical module A of the DOMU is not properly installed or is damaged.
  • Tributary No. 1: Optical module B of the DOMU is not properly installed or is damaged.

Procedure

  1. Reinstall the malfunctioning optical module of the DOMU.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Go to procedure 2.

  2. Replace the faulty optical module of the DOMU.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center


Huawei Proprietary and Confidential