ALM-4934 Transmit Mode Error Alarm

Description

The transmission mode configured on the SMT or BSC LMT is inconsistent with the optical transmission mode configured on the DMCM module.

Attribute

Alarm ID Alarm Severity Alarm Type
4934 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DOMU

3 Board No.

Number of the fault board

0-7:DOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

13:BTS3006C;

14:BTS3002E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Communication between the extension cabinet and the BSC is interrupted.

System Actions

None.

Possible Causes

The transmission mode set in the LMT is not consistent with the actual mode.

Procedure

  1. Set the transmission mode to E1 transmission mode in the LMT, or replace the DMCM. Check whether the alarm is cleared.

    Y=> The alarm is cleared. Alarm handling is completed..

    N=> The alarm is not cleared. Go to Step 2.

  2. Replace the DMCM and check whether the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential