ALM-5012 Optical Channel A Local Alarm

Description

The optical module A receives incorrect optical signals, and the performance goes down, or the services are interrupted. This alarm is reported.

Attribute

Alarm ID Alarm Severity Alarm Type
5012 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DOMU

3 Board No.

Number of the fault board

0-7:DOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

13:BTS3006C;

14:BTS3002E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services are interrupted and restored automatically, or the services are interrupted without restoration.

System Actions

None.

Possible Causes

The optical module A does not receive correct optical signals or the received signals are of bad quality.

Procedure

  1. Plug out the input optical fiber of the optical module A. Point the end to a white background and check whether there is a bright spot.

    Do not stare at the end of the optical fiber.

    Y=> Go to Step 2.

    N=> Check the equipment of the peer end or the optical transmission link. Rectify the fault according to the suggestions given in this Alarm.

  2. Insert the input optical fiber of the optical module A. Check whether the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Go to Step 3.

  3. Perform a loopback test on the input optical fiber and the output optical fiber of the optical module A. Check Weather the SFP A of the DMCM is off.

    Y=>Check the equipment of the peer end.

    N=>The alarm is not cleared. Go to Step 4.

  4. Replace the optical module A of the DMCM, and check whether the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Go to Step 5.

  5. Replace the DMCM and check whether the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.