ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 64:DOMU |
3 | Board No. | Number of the fault board 0-7:DOMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 13:BTS3006C; 14:BTS3002E; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The services are interrupted and restored automatically, or the services are interrupted without restoration.
The optical module A does not receive correct optical signals or the received signals are of bad quality.
Y=> Go to Step 3.
N=> Go to Step 4.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The reception of the equipment at the peer end is normal. Check the equipment at the peer end.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Go to Step 5.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.