ALM-5022 Optical Channel B Remote Alarm

Description

The optical module of the DOMU at the peer end does not receive correct optical signals, and the BTS transmission is interrupted temporarily or permanently. This alarm is reported.

Attribute

Alarm ID Alarm Severity Alarm Type
5022 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DOMU

3 Board No.

Number of the fault board

0-7:DOMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

13:BTS3006C;

14:BTS3002E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services are interrupted and restored automatically, or the services are interrupted without restoration.

System Actions

None.

Possible Causes

The optical module of the DOMU at the peer end does not receive correct optical signals or the received optical signals are of bad quality.

Procedure

  1. Clear the local alarm if there is any.

  2. Perform a loopback test on the input optical fiber and the output optical fiber of the optical module A, Check weather the SFP-A of the DMCM is off.

    Y=> Go to Step 3.

    N=> Go to Step 4.

  3. Replace the output optical fiber of the optical module B. Check whether the alarm is cleared.

    Y=> The alarm is cleared. Alarm handling is completed.

    N=> The reception of signals at the peer end is abnormal. Check the equipment at the peer end.

  4. Replace the optical module B of the DMCM. Check whether the alarm is cleared.

    Y=> The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared.Go to Step 5.

  5. Replace the DMCM and check whether the alarm is cleared.

    Y=> The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center.