ALM-5068 Board Initialization Failed

Description

The alarm is reported upon failure in chip initialization in the board.

Attribute

Alarm ID Alarm Severity Alarm Type
5068 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

87:GTMU

3 Board No.

Number of the fault board

0:GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • Critical If the only MPT cannot work normally, the services on the NodeB will be interrupted.
  • Major If the faulty board is not MPT, the services carried on the board are interrupted.
  • Minor Some minor functions of the board are not available.

System Actions

None.

Possible Causes

There maybe hardware fault existing with the board.

Procedure

  1. Reset the board.

    Reset the board. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling ends.

    N => The alarm is not cleared. Go to Step 2.

  2. Replace the board.

    Replace the board. Check whether the new board is available.

    Y => The new board is available. The alarm handling ends.

    N => The new board is not available. Please contact Huawei Customer Service Center.