ALM-5072 MPT Major Clock Abnormal

Description

This alarm is reported when the local MPT 10 MHz clock or the CPU working clock has no output or is faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
5072 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

87:GTMU

3 Board No.

Number of the fault board

0:GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0: Local MPT 10 MHz clock

1:CPU working clock

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • Critical:If the active MPT 10 MHz clock is faulty, the system automatically switches the clock source over to the standby 10 MHz clock. Stability of the system clock declines, and the success rate of service switchover also falls.
  • If the CPU working clock is faulty, the CPU cannot work.
  • Minor Current services are not affected, yet system reliability declines.

System Actions

  • When a critical alarm related to the active MPT is reported, the system handles the alarm as follows:
  • 1) If the NodeB has a standby MPT, the system performs active/standby switchover for the MPT.
  • 2) If the NodeB does not have a standby MPT, the system switches the current 10 MHz clock from the active clock over to the standby clock.
  • When the alarm reported is a critical one related to the standby MPT or a minor one related to the active or standby MPT, no system action is taken.

Possible Causes

There maybe hardware fault existing with the board.

Procedure

  1. Reset the MPT.

    Reset the MPT.Check whether the alarm is cleared

    Y => The alarm is cleared. End alarm handling.

    N => The alarm is not cleared. Go to Step 2.

  2. Replace the MPT.

    Replace the MPT.Check whether the alarm is cleared

    Y => The alarm is cleared. End alarm handling.

    N => The alarm is not cleared. Please contact Huawei Customer Service Center.