ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 87:GTMU |
3 | Board No. | Number of the fault board 0:GTMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: 4x clock abnormal 1: 32x clock abnormal 2: BFN abnormal |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Major If the board fails to work due to unavailable clock signals from both MPTs, all services carried on the board are interrupted.
Check whether there is such an alarm on multiple boards.
Y => The MPT is faulty. Go to Step 2.
N => The board is faulty. Go to Step 4.
Reset the MPT.Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling ends.
N => The alarm is not cleared. Go to Step 3.
Replace the MPT.Check whether the new board is available.
Y => The new board is available. The alarm handling ends.
N => The new board is not available. Please contact Huawei Customer Service Center.
Reset the board.Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling ends.
N => The alarm is not cleared. Go to Step 5.
Replace the board.Check whether the new board is available.
Y => The new board is available. The alarm handling ends.
N => The new board is not available.Please contact Huawei Customer Service Center.