ALM-5084 Board Clock Abnormal

Description

This alarm is reported when system detects that the board clock is abnormal, for example, the oscillator does not output clock, the secondary phase-lock cannot lock the main clock, the working clock is abnormal, and so on.

Attribute

Alarm ID Alarm Severity Alarm Type
5084 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

87:GTMU

3 Board No.

Number of the fault board

0:GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • Critical The board key oscillator clock or secondary phase-lock is abnormal. This may cause the board to fail to work.
  • Major Part of the board fails to work or the whole board cannot work normally.
  • Minor The board secondary oscillator clock is abnormal. The system can run normally but the reliability decreases.

System Actions

  • When the faulty code is 0, system automatically switches over to the standby crystal oscillator clock.
  • When the faulty code is 1, system doest not carry out any operation.
  • When the faulty code is 2, system sets the board as unavailable.
  • When the faulty code is 3, system sets the related ASIC as unavailable or the board as unavailable.

Possible Causes

The BBU hardware is faulty

Procedure

  1. Reset the board.

    Reset the board. Check whether the alarm is cleared:

    Y => The alarm is cleared. End alarm handling.

    N => The alarm is not cleared. Go to Step 2.

  2. Replace the board.

    Replace the board.Check whether the alarm is cleared

    Y => The alarm is cleared. End alarm handling.

    N => The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.