ALM-5090 Faulty Clock of the Phase-Lock Loop

Description

The corresponding phase-lock loop is unlocked.

Attribute

Alarm ID Alarm Severity Alarm Type
5090 Critical Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

87:GTMU

3 Board No.

Number of the fault board

0:GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0: 2306 Phase-lock loop is unlocked.

1: The 13 MHz phase-lock loop is unlocked.

2: The 32.768 MHz phase-lock loop is unlocked.

3: 22393 Phase-lock loop is unlocked.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm is generated, the main control module of the BTS fails to work properly.

System Actions

None.

Possible Causes

The hardware of the board is faulty.

Procedure

  1. Reset the MPT.

    Reset the MPT, and check whether the alarm is cleared.

    Y => If the alarm is cleared, the alarm handling is complete.

    N => If the alarm is not cleared, go to step [2].

  2. Replace the MPT.

    Replace the MPT, and check whether the fault in the board is rectified.

    Y => If the fault is rectified, the alarm handling is complete.

    N => If the fault persists, contact Huawei Customer Service Center.