ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 75:DFCU 76:DFCB |
3 | Board No. | Number of the fault board Value range:0-35 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When the alarm generates, the basic services proceed, but the downlink coverage goes down.
This alarm is reported if the interval between the frequency points of any two channels in the DFCU is less than 600kHz.
Y=>Reconfigure the channel frequency points and ensure the interval between any two frequency points is not less than 600kHz. Go to Step 2 Reset the DFCU.
N=>The alarm is not cleared, go to Step [3].
Reset the DFCU through the LMT, check whether the alarm is cleared.
Y=>The alarm handling ends.
N=>Go to step 2.
Y=> The alarm is cleared. Alarm Handling is completed.
N=> The alarm is not cleared. Please contact Huawei Customer Service Center.