ALM-5312 Board Type Mismatch

Description

The alarm is reported when the type of the board installed in the slot of the combining and distribution unit is inconsistent with the board type configured on the BSC.

Attribute

Alarm ID Alarm Severity Alarm Type
5312 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

66:DDPU/DDPM

75:DFCU

76:DFCB

3 Board No.

Number of the fault board

Value range:0-35

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm Sub-Category Number

Sub No. 0: The board installed in the slot is not the DUP unit.

Sub No. 1: The configured board is the DFCU, but the installed board is the DFCB.

Sub No. 255: The BTS detects that the configured board type in the DAFU subrack is inconsistent with the actual board type.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The board in this slot cannot run normally.

System Actions

None.

Possible Causes

  • Sub No. 0: The in-position board is not the DUP unit.
  • Sub No. 1: The DFCU or DFCB is mistakenly configured.
  • Sub No. 255: The BTS detects that the configured board type in the DAFU subrack is inconsistent with the actual board type.

Procedure

  1. Check the configuration information.

    On the LMT, check whether the configuration is consistent with the required configuration.

    Y => Consistent. Go to procedure 3.

    N => Inconsistent. Go to procedure 2.

  2. Modify the configuration on the LMT.

    Modify the configuration on the LMT, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to procedure 3.

  3. Replace the faulty or wrong DDPU/DDPM/DFCU.

    Replace the DDPU/DDPM/DFCU that generates the alarm with the correct module, and check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.


Huawei Proprietary and Confidential