ALM-5322 DUP Unit Clock Abnormal

Description

This alarm is reported when the total loading times of the DUP Unit programmable logic device exceeds the upper limit (3 times ).

Attribute

Alarm ID Alarm Severity Alarm Type
5322 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

66:DUP Unit

3 Board No.

Number of the fault board

Value range:0-35

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The board cannot be upgraded in a certain period of time.

System Actions

None.

Possible Causes

The DUP Unit is too frequently upgraded.

Procedure

  1. Retset the DUP Unit

    Reset the DUP Unit. check if the alarm is cleared.

    Y => The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared. Go to Step 2.

  2. Replace the DUP Unit

    Replace the DUP Unit. check if the alarm is cleared.

    Y => The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center.