ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 66:DUP Unit |
3 | Board No. | Number of the fault board Value range:0-35 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm Sub-Category Number Sub No. 0: The EPLD load on the DUP unit fails. Sub No. 1: The EPLD on the DUP unit cannot work normally. Sub No. 2: The internal memory of the DUP unit is faulty. Sub No. 3: Board internal communication alarm. Sub No. 4: The total loading times of the DUP unit programmable logic device exceeds 3 times. Sub No. 5: The circuit of the Path A or Path B Low Noise Amplifier (LNA) of the DUP unit is faulty. Sub No. 7: The cavity loss is excessive. |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The DUP Unit cannot detect the standing wave alarm or the forward power when the alarm occurs. The receive path may be abnormal.
Reset the DUP Unit. check if the alarm is cleared.
Y => The alarm is cleared. Alarm handling is completed.
N=> The alarm is not cleared. Go to Step 2.
Replace the DUP Unit. check if the alarm is cleared.
Y => The alarm is cleared. Alarm handling is completed.
N=> The alarm is not cleared. Please contact Huawei Customer Service Center.