ALM-5348 Cavity Board Type Mismatch

Description

This alarm is reported when either of the following situations occurs:The DFCU is configured in the BSC while actually the DFCB is installed in the BTS. The DFCB is configured in the BSC while actually the DFCU is installed in the BTS.

Attribute

Alarm ID Alarm Severity Alarm Type
5348 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

75:DFCU

76:DFCB

3 Board No.

Number of the fault board

Value range:0-35

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The system operates normally. But the TRX mutual-aid mechanism cannot be fully implemented.

System Actions

None.

Possible Causes

  • The DFCU is configured in the BSC while actually the DFCB is installed in the DFCB.
  • The DFCB is configured in the BSC while actually the DFCU is installed in the DFCB.

Procedure

  1. Install the DFCU or DFCB based on the configuration from the BSC and check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> The alarm persists. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.