ALM-5652 PSU Safeguard Alarm

Description

This alarm is reported when the power module in the Sidepower system has a temperature alarm or a fan alarm. The yellow indicator is on when this alarm is generated.

Attribute

Alarm ID Alarm Severity Alarm Type
5652 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

72:DPMU

133:APM/APMU

3 Board No.

Number of the fault board

Value range:0-8:DPMU/APMU/APM

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number.

Sub No.0: Power Supply Unit (PSU) 0 communication alarm.

Sub No.1: PSU 1 communication alarm.

Sub No.2: PSU 2 communication alarm.

Sub No.3: PSU 3 communication alarm.

Sub No.4: PSU 4 communication alarm.

Sub No.5: PSU 5 communication alarm.

Sub No.6: PSU 6 communication alarm.

Sub No.7: PSU 7 communication alarm.

Sub No.8: PSU 8 communication alarm.

Sub No.9: PSU 9 communication alarm.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

The temperature of the power module in the Sidepower system exceeds the upper threshold (55 ℃).

Procedure

  1. Check for the over voltage or under voltage alarms of the –48 V DC power.
    1. Check whether the –48V abnormal voltage alarms exist:

      Y => The precedent alarms exist. Go to step b.

      N => The precedent alarms do not exist. Go to procedure 2.

    2. Handle the –48 V abnormal voltage alarms.
    3. Check whether the alarm is cleared:

      Y => The alarm is cleared. The alarm handling ends.

      N => The alarm is not cleared. Go to procedure 2.

  2. Replace the faulty PSU.
    1. Replace the faulty PSU.
    2. Check whether the alarm is cleared:

      Y => The alarm is cleared. The alarm handling ends.

      N => The alarm is not cleared. Contact Huawei Customer Service Center.