ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 72:DPMU |
3 | Board No. | Number of the fault board Value range:0-8:DPMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 15:BTS3012AE; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When this alarm is generated, the power lightning arrester module in the power system is already damaged. The ability of the lightening arrester decreases. When the lightning strike occurs again, the BTS services may be interrupted.
This alarm is generated when the AC lightning arrester in the power system is faulty.
Y=> Go to step 2.
N=> Go to step 3.
Y=> The alarm is cleared. The alarm handling is complete.
N=> Go to step 3.
Y=>The alarm is cleared. The alarm handling is complete.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.