ALM-5858 PMU Communication Alarm

Description

This alarm is triggered when the communication between the TMU and the PMU is interrupted.

Attribute

Alarm ID Alarm Severity Alarm Type
5858 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

72:DPMU

133:APMU

3 Board No.

Number of the fault board

Value range:0-8:

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

3:BTS30;

5:BTS312;

10:BTS3012A;

11:BTS3006A;

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The BTS cannot monitor the PMU and the PSU upon the occurrence of this alarm.

System Actions

None.

Possible Causes

  • The DIP switches of the PMU are incorrect.
  • The communication cable of the PMU is incorrectly connected.
  • The MON1 port of the UPEU board is faulty.
  • The software of the main control board is faulty.

Procedure

  1. All the cables are correctly connected.
    1. Check whether the DIP of the PMU is correct.
    2. Check the port on the APMI to which the BBU is connected. Ensure that all the cables are correctly connected.
    3. Check the MON1 port to which the BBU is connected. Ensure that the cable is not connected to the MON0 port.
    4. Check the RJ45 port on the panel of the PMU. The RJ45 port should be connected to the RS232 port and the RS422 port. (You are recommended to the connect the cable to the port on the left.)
    5. Check whether the alarm is cleared:

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to step 2.

  2. Check whether the heat exchanger board communication alarm is generated on the BSC side.

    Y = > The alarm is generated. Replace the UPEU board (the MON port is faulty). Check whether the alarm is cleared:

    Y => The alarm is cleared. No further action is required.

    N = > The alarm is not cleared. The main control board might be faulty. Clear the alarm according to the troubleshooting procedure of the main control board.

  3. The alarm is not cleared. Contact Huawei Customer Service Center.